quire

User Guide

Introduction

The EverFocus EAR-100T7 is an AI Box powered by NVIDIA® Jetson AGX THOR, purpose-built for AMR (Autonomous Mobile Robot) applications. Featuring an Arm Neoverse V3AE CPU and Blackwell GPU, it delivers strong AI performance for real-time navigation.

With GMSL2 camera inputs, CAN FD, multiple GbE ports, and 5G/GPS support, the EAR-100T7 enables seamless sensor integration and precise synchronization. Its rugged design, 19–36VDC power input, and extended temperature range make it ideal for industrial AMR deployment in logistics and automation.

Features

EAR-100T7

  • Fan AI edge embedded box PC
  • NVIDIA Jetson T5000 Blackwell GPU + Arm Neoverse V3AE CPU
  • 128 GB (8 x 16 GB) memory with 256-bit LPDDR5X DRAM
  • Supports 12 x GMSL Camera
  • Supports M.2 M-key 2280 x 1 (for NVMe SSD)
  • Supports M.2 B-key 3052 x 1 (for 4G/5G module)
  • Supports M.2 E-key 2230 x 1 (for Wi-Fi/BT module)
  • Supports HDMI 2.0 x 1
  • Supports USB 3.2 x 4 (Type-A)
  • Supports 2 x 5 GbE LAN (RJ45)
  • Supports 2 x CAN bus
  • Supports Speaker & Microphone input (optional)
  • Supports 19V to 36V DC input

Refer to Chapter 3 Specification for more detail.

Dimensions

Packing List

  • AI BOX x 1
  • Mounting Bracket x 2
  • Screw Kit x 1
  • Terminal Block (Power / CAN BUS)

Note:

  1. Equipment configurations and supplied accessories vary by country. Please consult your local EverFocus office or agents for more information.
  2. If any item appears to have been damaged in the shipping process, please contact the shipper. Please also keep the shipping carton for possible future use.

Physical Description

No. Name Description
1 PWR Input Connecting to the power source
2 USB 4 x USB 3.2,Type A (optional)
3 CAN BUS 1 x CAN BUS
4 HDMI 1 x HDMI 2.0 output
5 LAN 2 x 5 GbE LAN port
6 Audio 1 x Line out
1 x MIC in (optional)
7 Indicator 2 x LED light (PWR/Status)
8 GMSL 12 x GMSL2

No. Name Description
9 Antenna ANT1~ANT7
ANT1~ANT4 ANT5 ANT6~ANT7
5G Module GPS WIFI

No. Name Description
10 Protective Cover Remove the cover to access the following slots
1 x SIM card
11 Button 1 x Force Recovery ; 1 x Reset ; 1 x Power

Jumpers and Connectors

Mother board


Mother board TOP and BOTTOM
CN1 19~36V DC Power Input CN16 Automation Header
CN2 NVIDIA Jetson AGX Thor SOM module CN17 FAN Connecter
CN3 JTAG Programming connector CN18 Board to Board connecter
CN4 Botton MCU Programming connector CN19 RJ45-1(5GbE)
CN5 Video out (HDMI) CN20 RJ45-2(5GbE)
CN6 M.2 M key 2280 Slot(NVME) CN32 Debug MCU Programming connector
CN7 M.2 E Key 2230 Slot (WiFi) CN33 Thor SOM module Debug connecter
CN8 M.2 B+M Key 3052 Slot (4G/5G) CN34 TSMC control Single Connecter
CN9 SIM Card Slot (SD Card N/A) SW1 Power ON Button
CN10 CAN BUS SW2 Reset Button
CN11 Audio In/Out SW3 Force Recovert Button
CN12 USB 3.2 Gen1 TypeA *2 LED1 Internal Power LED
CN13 USB 3.2 Gen1 TypeA *2 LED2 External Power LED & GPIO Control LED
CN14 OTG USB Type C CN27 12V Power to GMSL
CN15 RTC Battery connecter

Mother board Pin Assignment

Power Input
1 2 3
VIN GND GND_E
CAN BUS
1 2
CAN1_L CAN1_H
3 4
CAN2_L CAN2_H
JTAG Header
1 2
VDD_1.8V JTAG_TMS
3 4
GND JTAG_TCK
5 6
GND JTAG_TDO
7 8
GND JTAG_TDI
9 10
GND SYS_RST
Automation Header
1 2 3
GND FORCE_RECOVERY_N STS_RST_IN_N
4 5 6
BUTTON_POWER_ON CCG4_LED ACOK_CON
7 8 9
CVB_STBY SYSTEM_OC_N_BU ETH_WOL_EN_N
10 11 12
GND JTAG_TRST_N GND
TSMC Control Single
1 2 3 4 5 6
GND GPIO I2C_DATA I2C_CLK URAT_TX UART_RX
UART Debug
1 2 3 4
GND UART_TX UART_RX 3.3V
RTC Battery
1 2
RTC_BAT GND
12V Power
1 2 3 4
12V 12V GND GND
FAN Control
1 2 3 4
GND VDD TACH PWM

GMSL Board

GMSL board TOP and BOTTOM
CN1 12V DC Power Input CN11 GMSL 2 camera FAKRA Z code
CN2 12V Power to TSMC Main Board CN12 GMSL 2 camera FAKRA Z code
CN3 Board to Board Connecter CN13 GMSL 2 camera FAKRA Z code
CN4 PWM Single to TSMC Main Board CN14 GMSL 2 camera FAKRA Z code
CN5 GMSL 2 camera FAKRA Z code CN15 GMSL 2 camera FAKRA Z code
CN6 GMSL 2 camera FAKRA Z code CN16 GMSL 2 camera FAKRA Z code
CN7 GMSL 2 camera FAKRA Z code SW1 CFG Settings Switch
CN8 GMSL 2 camera FAKRA Z code SW2 CFG Settings Switch
CN9 GMSL 2 camera FAKRA Z code SW3 CFG Settings Switch
CN10 GMSL 2 camera FAKRA Z code

GMSL Board Pin Assignment

PWM Single connector
1 2 3 4 5 6 7 8
PWM_1 GND PWM_2 GND PWM_3 GND PWM_4 GND
12V Power
1 2 3 4
12V 12V GND GND
12V Power
1 2 3 4
12V 12V GND GND

SW1 / SW2 / SW3
1 2 3 4
ON ON ON ON

Specification

System
CPU/GPU NVIDIA Jetson T5000 Blackwell GPU + Arm Neoverse V3AE CPU
Memory 128 GB (8 x 16 GB) memory with 256-bit LPDDR5X DRAM
Storage 1 x M.2 M-Key 2280, support NVMe
Real time clock Yes
Indicators 1 x LED indicator (Power)
Wireless 1 x M.2 E-Key 2230, Wi-Fi/BT
1 x M.2 B-Key 3052, 4G/5G
Operating System NVIDIA JetPack™ 7.0
Security TPM 2.0
Power Supply
Power Requirement 19 ~ 36 VDC
Power Consumption TBD
MTBF (Hours) --
Environmental and Mechanical
Dimension 200 x 145 x 87 mm (7.87” x 5.7” x 3.42”)
Weight TBD
Mouting/Installation Wall Mount
Operating Temperature -20 ~ 60 °C (-4 ~ 140 °F)
Storage Temperature -40 ~ 85 °C (-40 ~ 176 °F)
Operating Humidity 10% ~ 95% relative humidity, non-condensing
Certification
Regulations CE, FCC
Interface
GMSL Camera 12 x FAKRA Z code with frame syn
CAN Bus 2 x CAN-FD
Ethernet 2 x 5 GbE LAN, RJ45
USB 4 x USB 3.2, Type-A (Optional)
Audio 1 x speaker
1 x Mic in (Optional)
Display 1 x HDMI 2.0-Out
Power Connector 3-pin Terminal Block
Debug Port 1 x Micro USB
SIM Slot 1 x Nano SIM Card Socket
Expansion Slot 1 x M.2 E-key (2230) for Wi-Fi/BT
1 x M.2 M-key (2280) for NVMe SSD
1 x M.2 B-key (3052) for 4G/5G
Other Interface Build in IMU, GNSS

BSP Flash Guide

Before Installation

Before starting the process, make sure your EAR-100T7 system is turned off and the power in is disconnected. You will need a Host PC running Ubuntu 22.04/24.04, and to make sure the NVIDIA Jetson AGX Thor module is installed on the EAR-100T7 carrier board system.

Note: Do not use a virtual machine as a host PC, as some virtual machines may have unstable USB connections which can cause the flash procedure to fail.

Download the compressed BSP image file “mfi_jetson_agx_thor_devkit.tar.gz” into the Host Ubuntu 22.04/24.04 PC directory

Note:

1. No spaces, special characters, or non-English characters can be used for the name of the folder where the file is stored, or its parent folder.

2. Ensure the language settings of Ubuntu 22.04/24.04 are set to English, and the format setting is the United States, to prevent flash failure.

Connecting to PC/Force Recovery Mode

  • Step 1:

On the Host computer, open the Linux terminal and enter the following command to extract the compressed BSP image files (BSP file name may vary):

$ sudo tar -zxvf mfi_jetson_agx_thor_devkit.tar.gz

Note: Do not decompress the file (i.e. FAT NTFS exFAT) using a Windows OS, BSP should only be decompressed in a Linux EXT3/4 file system.

  • Step 2:

Perform the following actions to force the system to start in USB Recovery Mode:

1. Connect the Type-C USB plug on the USB cable to the Recovery Port on the EAR-100T7, and the other end to an available USB port on the Host PC.

2. Connect the EAR-100T7 to a power supply.

3. Press and hold the recovery key button. While holding the recovery key button, power on the system, and continue to hold the recovery key button for two seconds, then release. The EAR-100T7 should then enter recovery mode.

4. To check if device is in recovery mode, enter the command lsusb in terminal on Host

$ lsusb |grep "0955:7026"

If successful, the command will return “0955:7026 Nvidia Corp. APX”

Note: Recovery mode cannot be initiated if the NVIDIA Jetson AGX Thor module is disassembled. Ensure the NVIDIA Jetson AGX Thor module is installed and refer to the image below to perform the force recovery mode steps:

Flash Image to Board

Use the following steps to flash the OS to the EAR-100T7:

1) Open terminal on the Ubuntu Host PC, then access the folder you extracted in the previous section.

2) Enter the following command in terminal to flash 1 jetson device:

$ sudo ./l4t_initrd_flash.sh --flash-only --massflash 1 --network usb0 jetson-agx-thor-devkit --showlogs

Note: You can modify the number after “--massflash” to flash up to 3 devices simultaneously.

Ex:

$ sudo ./l4t_initrd_flash.sh --flash-only --massflash 3 --network usb0 jetson-agx-thor-devkit --showlogs

3) Wait as the image is installed. Once complete you should see “Flashing finished Successfully” as the following:

Check BSP Version

Once the flash image is successfully installed, you should turn off the power of the EAR-100T to reboot, then check the BSP version to see if the system is flashing the correct version of BSP

Open a Terminal, and type command cat /proc/product

You will see the product name with version and date

EAR-100T7-00-208N08_JP7.0_v1.0_20250828

Note: Product names may vary based on hardware revisions or software images. For more details, please consult with our Sales/FAE.

Build BSP from Source (JetPack 7.2)

The steps above flash the pre-built BSP image provided by EverFocus. If you need to customize the kernel, device tree, or root file system, or want to move to JetPack 7.2 (L4T R39.2.0), build the BSP from source instead.

Requirements

  • Host PC running Ubuntu with the tools listed in the NVIDIA Jetson Linux Developer Guide, plus curl and xclip
  • An SSH key registered on the EverFocus GitLab, used to clone the BSP source and customization repositories
  • The NVIDIA cross-compile toolchain (x-tools)

Overview

  1. Clone the Jetson Thor BSP source (branch 100t) and set up the toolchain.
  2. Download the customized root file system and build the kernel, kernel modules and device tree.
  3. Build the firmware version module (PRODUCT_INFO) and install it into the root file system.
  4. Flash the board directly, or generate a release image (mfi_jetson-agx-thor-devkit.tar.gz) and flash it with the same procedure as Flash Image to Board.
  5. Optionally generate an OTA package (requires flashing with ROOTFS_AB=1).

For the full commands and notes, see Build BSP from Source (JetPack 7.2).

OS User Guide

Introduction

The EAR-100T7’s OS, Ubuntu/Linux version, and pre-installed SDK components are as following:

For Jetpack 7.0 (l4t 38.2.1)

  1. Ubuntu/Linux version
    1. Ubuntu version: 24.04.3
    2. Kernel version: 6.8.12-tegra
    3. UEFI version: 38.2.1-gcid-42061081
  2. Built-in all Jetson SDK Components
    1. Gstreamer 38.2.1
    2. Jetson Camera SIPL 38.2.1
    3. CUDA Toolkit 13.0
    4. cuDNN 9.12
    5. TensorRT 10.13
    6. OpenCV 4.8
    7. CuPVA Runtime 2.7
    8. VPI 4.0.0NVIDIA Container Runtime 1.18
    9. Multimedia API 38.2.1
    10. Nsight Systems 2025.5
    11. Deepstream 8.0
    12. GXF Runtime 5.1.0

NOTE: For more detail information, please visit Nvidia website: https://developer.nvidia.com/embedded/jetpack/downloads/archive-7.0

Default login user/password:

Account: nvidia

Password: nvidia

Update Note

Running $ sudo apt upgrade command in terminal will overwrite the EverFocus kernel device tree (.dtb)/kernel image (Image)/bootloader in the OS, which can lead to unexpected results, including the loss of I/O ports.

EverFocus has disabled the NVIDIA apt repository by default to prevent customers from performing unintended upgrades to NVIDIA packages.

Please contact your EverFocus representative to obtain the latest BSP for your system.

Connector Testing Command

  • PWM Control
  1. Stop NV fan control daemon
$ sudo systemctl stop nvfancontrol
  1. Set PWM value
$ echo [PWM_duty_cycle] > /sys/devices/platform/pwm-fan/hwmon/hwmon<x>/pwm1

Where: [PWM_duty_cycle] is a value in the range [0,255]. <x> is a kernel enumerated number for fan hwmon

  • Canbus Transceive
  1. receive message

ex:

$ candump -x any &
  1. transmit message

ex:

$ cansend can0 123#abababab

Debug Console

The debug console gives you access to the boot log (UEFI/kernel messages) and a login shell even when no display or network is available. It is useful when the system does not boot, after flashing a new BSP, or when diagnosing hardware issues.

The EAR-100T7 provides two ways to connect:

  • Debug USB (CN14, USB Type-C): connect CN14 to the host PC with a USB Type-C cable. The console appears on the host as a USB serial device (for example /dev/ttyACM0 on Linux, or a COM port on Windows). No extra adapter is required.

Open a serial terminal on the host PC with these settings: 115200 baud, 8 data bits, no parity, 1 stop bit, no flow control. For example, on Ubuntu:

$ sudo apt install screen
$ sudo screen /dev/ttyACM0 115200

  • Debug UART (CN33): connect a 3.3V USB-to-TTL serial adapter. Connect GND to GND, TX to the adapter's RX, and RX to the adapter's TX. Do not connect the 3.3V pin, and do not use an RS-232 adapter (±12V) — it can damage the board.

Open a serial terminal on the host PC with these settings: 115200 baud, 8 data bits, no parity, 1 stop bit, no flow control. For example, on Ubuntu:

$ sudo apt install screen
$ sudo screen /dev/ttyUSB0 115200

Then power on the EAR-100T7; the boot messages appear in the terminal, followed by the login prompt (default account: nvidia / nvidia).

Safety and Regulatory Information

Disclaimer

All the images including product pictures or screen shots in this document are for example only. The images may vary depending on the product and software version. Information contained in this document is subject to change without notice.

All rights reserved. No part of the contents of this manual may be reproduced or transmitted in any form or by any means without written permission of the EverFocus Electronics Corporation.

  • NVIDIA, the NVIDIA logo, and Jetson are trademarks of the NVIDIA Corporation

  • ITE is a trademark of Integrated Technology Express, Inc.

  • IBM and VGA are trademarks of International Business Machines Corporation.

  • Ubuntu is a registered trademark of Canonical

  • All other product names or trademarks are properties of their respective owners.

Safety Precautions

Please read the following safety instructions carefully. It is advised that you keep this manual for future references.

  • All cautions and warnings on the device should be noted.

  • All cables and adapters supplied by EverFocus are certified and in accordance with the material safety laws and regulations of the country of sale. Do not use any cables or adapters not supplied by EverFocus to prevent system malfunction or fires.

  • Make sure the power source matches the power rating of the device.

  • Position the power cord so that people cannot step on it. Do not place anything over the power cord.

  • Always completely disconnect the power before working on the system’s hardware.

  • No connections should be made when the system is powered as a sudden rush of power may damage sensitive electronic components.

  • If the device is not to be used for a long time, disconnect it from the power supply to avoid damage by transient over-voltage.

  • Always disconnect this device from any AC supply before cleaning.

  • While cleaning, use a damp cloth instead of liquid or spray detergents.

  • Make sure the device is installed near a power outlet and is easily accessible.

  • Keep this device away from humidity.

  • Place the device on a solid surface during installation to prevent falls.

  • Do not cover the openings on the device to ensure optimal heat dissipation.

  • Watch out for high temperatures when the system is running.

  • Do not touch the heat sink or heat spreader when the system is running.

  • Never pour any liquid into the openings. This could cause fire or electric shock.

  • As most electronic components are sensitive to static electrical charge, be sure to ground yourself to prevent static charge when installing the internal components. Use a grounding wrist strap and contain all electronic components in any static-shielded containers.

  • If any of the following situations arises, please contact our service personnel (ts@everfocus.com.tw):

    • Damaged power cord or plug

    • Liquid intrusion to the device

    • Exposure to moisture

    • Device is not working as expected or in a manner as described in this manual

    • The device is dropped or damaged

    • Any obvious signs of damage displayed on the device

  • DO NOT LEAVE THIS DEVICE IN AN UNCONTROLLED ENVIRONMENT WITH TEMPERATURES BEYOND THE DEVICE’S PERMITTED STORAGE TEMPERATURES (SEE SPECIFICATION) TO PREVENT DAMAGE.

FCC Statement

This device complies with Part 15 FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation.

Caution: There is a danger of explosion if the battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions and your local government’s recycling or disposal directives.

Attention: Il y a un risque d’explosion si la batterie est remplacée de façon incorrecte.

Ne la remplacer qu’avec le même modèle ou équivalent recommandé par le constructeur. Recycler les batteries usées en accord avec les instructions du fabricant et les directives gouvernementales de recyclage.